Splunk AppDynamics On-Premises Virtual Appliance Known Issues

This section lists the known issues in Virtual Appliance 25.10.

This section lists the known issues in Virtual Appliance 25.10.

Virtual Appliance Upgrade Fails Due to Missing Configuration Settings and Errors

Issue ID Component Severity Affected Version
NEXUSOP-1769 Virtual Appliance Medium 25.10.0

The upgrade to Virtual Appliance version 25.10.0 fails due to missing configuration settings and errors in the globals.yaml.gotmpl file:

  • Missing migration.elasticsearch.fs section.

  • Missing customActions section.

Workaround:

If you are upgrading Virtual Appliance from 25.7:

Before starting the Virtual Appliance services, add the below section in globals.yaml.gotmpl:

CODE
# Migration config for datastores
migration:
  elasticsearch:
    fs:
      enabled: false
      mountPath: /mnt/nfs_events

If you are upgrading Virtual Appliance from the versions lesser than 25.7:

Before starting the Virtual Appliance services, add the following sections in globals.yaml.gotmpl:

CODE
# Migration config for datastores
migration:
  elasticsearch:
    fs:
      enabled: false
      mountPath: /mnt/nfs_events
CODE
customActions: 
  enable: true
  storage: 2Gi 
  path: /var/appd/data/custom-actions/actions/
Then start the services:
CODE
appdcli start appd <profile>